#1 Construction Agency

Advanced Early Fire Detection & Intelligent Life Safety Systems in KSA

We design, supply, install, and commission advanced fire alarm and early detection infrastructure across Saudi Arabia. Operating in strict accordance with the Saudi Building Code (SBC 801), NFPA Standards (72, 75, 76), and Saudi Civil Defense (Salamah / 998) requirements, our life safety networks identify thermal risks, smoke, and combustible gas buildup at the incipient stage to alert occupants, initiate containment protocols, and prevent asset loss.

about our company

Intelligent Life Safety Systems Compliant with SBC 801 & NFPA 72

A certified life safety network integrates high-precision sensing devices with centralized command units to deliver continuous, real-time environmental monitoring across complex facility layouts.

what we do

Engineering, Cause-and-Effect Logic & CAD Layouts

Every installation begins with precise risk evaluation and loop-loading calculations. Our engineering team designs Cause-and-Effect logic matrices, battery backup calculations, and voltage-drop analyses to ensure loop reliability and rapid Saudi Civil Defense design approval.

Multi-Criteria Sensors & Detectors

Photoelectric smoke, rate-of-rise heat, optical flame, and gas monitors tracking physical and chemical ambient shifts.

Fire Alarm Control Panels (FACP)

Addressable units that evaluate inputs, pinpoint device locations, run diagnostic checks, and trigger interlocks.

Notification & Emergency Voice Evacuation (VES)

High-decibel sirens, synchronized strobes, and multi-zone VES units delivering clear emergency instructions.

Manual Call Points (MCP)

Break-glass units along egress routes for manual alarm initiation.

Cross-System Integration & Automated Control Protocols

Modern life safety networks rely on automated interlocks between the FACP and building management systems to contain fire threats and protect evacuation corridors.

Fire Protection Systems Company Saudi Arabia | TRIAD
  • Integrated Subsystem

    What the Fire Alarm Control Panel (FACP) does automatically

  • HVAC & Smoke Control

    Shuts off fresh air intake and starts stairwell smoke extraction fans.

  • Access Control & Egress

    Unlocks access-controlled doors and recalls elevators to the designated floor (Phase 1 recall).

  • Civil Defense Dispatch

    Sends the fire alarm to the Civil Defense monitoring center over two communication paths (IP + cellular).

  • Suppression Systems

    Activates the fire suppression system (clean agent gas, deluge system, etc.).

Our LOCATIONS

Nationwide Coverage Across Saudi Arabia

CENTRAL REGION

1- Riyadh City
2- MODON Industrial Cities 1, 2, 3
3- Sudair Hub

Western Region

1- Jeddah Port Zone
2- Yanbu Petrochemical Area
3- KAEC / Rabigh

Eastern Province

1- Jubail Industrial City
2- Dammam Ports
3- Ras Al-Khair

Southern Hub

1- Jazan Economic City
2- Asir Region
3- Najran Zone

Northern Zone

1- NEOM Project
2- Tabuk Hub
3- Wa'ad Al Shamal

Join Buildra

High-Sensitivity Detection Arrays for High-Value Assets

For high-value, mission-critical assets, we deploy Performance-Based Engineering (PBE) with specialized high-sensitivity arrays to achieve business continuity and rapid threat neutralization.

Aspirating Smoke Detection (ASD / VESDA)

Actively draws air samples into a central laser chamber, detecting microscopic particles (0.005% to 20% obscuration/m) long before visible smoke appears.

Infrared (IR) & Thermal Imaging Detection

Monitors surface heat radiation (W/m²) across open spaces to pinpoint anomalies without line-of-sight dust interference.

Fiber-Optic Linear Heat Detection (LHD)

Sensor cables delivering meter-by-meter temperature tracking over long distances, unaffected by Electromagnetic Interference (EMI).

Get Started

Regulatory Maintenance & Civil Defense Handover

  • Daily / Continuous: Automated FACP diagnostic monitoring of power, ground faults, and loop continuity.
  • Quarterly (SBC 801): Functional testing of 25% of initiation devices, MCPs, notification units, and batteries.
  • Annual (NFPA 72): 100% integration testing of Cause-and-Effect logic, HVAC tripping, and detector sensitivity.
  • Official Logbook: All maintenance logs must be maintained in an official Site Fire Safety Logbook for Saudi Civil Defense audits.
Contact Us

Request an Engineering Proposal

Ensure your life safety infrastructure complies with SBC 801 standards and Civil Defense guidelines. Submit project requirements to receive an itemized BOQ proposal backed by full engineering support.

Submit your CAD drawings or building specifications for a complete









    Your information is confidential and handled securely.

    Bahrah, 23342, Jeddah, KSA

    sales@triad.sa

    Monday – Friday, 8:00 AM – 5:00 PM (AST)

    Common Questions

    Frequently Asked Questions (FAQs)

    Still Have Any Questions?
    General Questions
    What is the primary difference between conventional and addressable fire alarm systems?

    Conventional systems group detectors into general zones, whereas addressable systems assign a unique digital address to every detector, pinpointing the exact location of a fire event instantly.

    VESDA is used in mission-critical or high-airflow environments (like data centers and high-bay warehouses) where early detection is critical before visible smoke forms.

    Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

    Salamah portal licensing typically takes 5 to 10 business days after testing, subject to compliant CAD drawings, UL/FM certificates, and physical inspection.