We deliver end-to-end fire protection engineering, supply, installation, testing, commissioning, and Civil Defense certification across Riyadh, Al-Kharj, Sudair, and the wider Central Region. Designed in strict compliance with the Saudi Building Code (SBC 801 Fire Code), High Commission for Industrial Security (HCIS Directives), NFPA Standards, and Saudi Civil Defense (Salamah) mandates, our life safety solutions protect high-density commercial towers, government IT infrastructure, mission-critical data centers, and major MODON logistics parks.
Riyadh’s rapid expansion demands high-performance, compliant fire safety architectures engineered for high-occupancy skyscrapers, government facilities, and vast logistics hubs.

Hotels and commercial dining facilities require dedicated protection mechanisms for specialized hazard areas.

Environmentally safe, clean agent systems engineered for high-density electrical rooms, data halls, and critical control centers.
Heavy-duty ceiling sprinkler networks designed for high-bay rack storage, cold chain facilities, and logistics centers.
Fully addressable, multi-channel voice alarms compliant with Civil Defense standards for clear, phased building evacuation.


Our life safety engineering services extend across major hospitality hubs, mega-projects, and commercial centers throughout the Kingdom.
Submit your building layouts, architectural CAD files, or technical BOQs for an itemized commercial and engineering proposal tailored to your Central Region project.

Bahrah, 23342, Jeddah, KSA
sales@triad.sa
Monday – Friday, 8:00 AM – 5:00 PM (AST)
Clean agent fire suppression systems using Novec 1230 (FK-5-1-12) or Inergen (IG-541) are the standard for server rooms and data halls. They extinguish fires within seconds without leaving residue, conducting electricity, or damaging sensitive electronic hardware, fully aligning with NFPA 75 and NFPA 2001.
ESFR (Early Suppression Fast Response) sprinklers deliver high-volume, high-velocity water droplets directly through rising fire plumes. They eliminate the need for in-rack sprinklers in many high-bay storage setups up to 40-45 feet high, lowering installation costs while satisfying SBC 801 and NFPA 13 requirements.
We conduct initial site surveys, review CAD plans against SBC 801, install or upgrade approved equipment, perform mandatory testing (such as hydrostatic pressure tests and alarm signaling loops), and upload certified inspection reports directly to the Salamah portal for official permit issuance.